The Short Version

Decide how warm the greenhouse must stay first: aim for 40°F for frost protection, while 55 to 65°F at night is adequate for most greenhouse plants. Then estimate heat loss as surface area × U-value × temperature difference, plus air leaks and the base perimeter.

Our worked example, an 8×12 twin-wall polycarbonate kit held at 45°F on a -10°F night, needs about 14,100 Btu/hr, or roughly 4.1 kW. That is close to the output of three 1,500-watt plug-in heaters, a measure of electrical demand rather than a recommended setup, so insulate and seal before you shop.

Skip to the heat-loss worked example ›

It is tempting to buy a heater first and find out on the first hard freeze whether it keeps up. Work backwards instead: pick the lowest temperature your plants can tolerate, estimate how fast the structure loses heat on your coldest nights, cut that loss where it is cheap, and only then choose a heater and a safe way to power or vent it. Below are the standard engineering figures, a worked example for a common 8×12 kit, and an honest look at each heater type.

Decide the Minimum Temperature First

The thermostat setting drives your heating bill, because heat loss rises in direct proportion to the gap between inside and outside temperature. There are two broad targets.

A frost-free greenhouse simply keeps plants from freezing. If you want no more than frost protection, set the thermostat at 40°F, or about 4°C (39°F) if you work in Celsius. Frost-free conditions let you overwinter more tender plants.

A warm growing greenhouse keeps plants actively growing. A night temperature of 55 to 65°F is adequate for most greenhouse plants, with sunny-day temperatures 10 to 15°F higher. Raising the night setting from 40°F to 60°F adds 20 degrees to the temperature difference, which in a mild climate can double the load. If you mainly want early seedlings, a short heated season in late winter can cost far less than holding 60°F from December on. Our greenhouse growing calendar shows which crops fit each approach.

Leave a margin. Heater thermostat dials may be off by a few degrees because they sit close to the heater, so the worked example below uses 45°F rather than 40°F.

How to Estimate Your Greenhouse’s Heat Loss

Heat leaves a greenhouse three main ways: conduction through the glazing and walls, air leaking in and out, and conduction into the ground along the base. The standard method estimates each one and adds the three together.

  • Conduction loss (Btu/hr) = surface area (sq ft) × U-value × temperature difference (°F)
  • Air leakage loss (Btu/hr) = 0.02 × volume (cu ft) × air changes per hour × temperature difference
  • Perimeter loss (Btu/hr) = perimeter length (ft) × perimeter factor × temperature difference

The temperature difference is your inside setting minus the coldest night you plan for. The U-value is how much heat a material lets through per square foot per degree; lower is better.

U-Values for Common Glazing

These values come from Rutgers and University of Wisconsin extension publications. Where they differ slightly, the range is shown.

Material U-value (Btu/hr·ft²·°F) Notes
Single-layer glass 1.1 Baseline for comparison
Single-layer polyethylene film 1.1 to 1.2 Rutgers lists 1.1, Wisconsin 1.2
Double-layer glass 0.7 Sealed or spaced double glazing
Double-layer polyethylene film 0.7 Two layers separated by air
Twin-wall polycarbonate (6 to 10 mm) 0.53 to 0.63 Rutgers lists 0.6 for double-layer panels
Triple-wall polycarbonate (8 to 16 mm) 0.42 to 0.53 Better insulation, less light
Double layer plus energy curtain 0.3 to 0.5 Curtain drawn at night; applies only to the surfaces it covers
8-inch concrete block 0.5 Common knee wall or base
2-inch polystyrene board (R-10) 0.1 For opaque walls and the base

Some hobby kits use 4 mm twin-wall polycarbonate, thinner than the 6 to 10 mm range in the table above, and it can insulate less well than that range suggests. Palram lists a U-value of 3.8 W/m²K for its 4 mm SUNLITE twin-wall sheet, which converts to about 0.67 Btu/hr·ft²·°F. Get the U-value for your own panels from the spec sheet or the manufacturer. The worked example below uses the Rutgers figure of 0.6; at 0.67 its total rises to about 15,400 Btu/hr. For how thickness affects insulation and light, see Glazing Thickness Explained and Polycarbonate vs Glass.

Worked Example: An 8×12 Kit in a Cold Region

Take an 8×12 kit with 5.5-foot walls, a 7.5-foot ridge and twin-wall polycarbonate throughout, held at 45°F on a -10°F night: a 55°F difference. The dimensions are illustrative, so substitute your own.

The glazed surface works out to about 343 square feet: 132 for the two long walls, 104 for the two end walls including the gables, and 107 for the roof. The volume is about 624 cubic feet and the perimeter is 40 feet. For air leakage we use 1.5 air changes per hour, the top of the typical range for new glass construction, as a cautious figure for a kit with a door and roof vents. For the base we use the standard factor for an uninsulated perimeter, 0.8.

Heat-loss component Calculation Btu/hr
Glazing (twin-wall polycarbonate) 343.3 × 0.6 × 55 11,330
Air leakage 0.02 × 624 × 1.5 × 55 1,030
Uninsulated perimeter 40 × 0.8 × 55 1,760
Total, twin-wall polycarbonate about 14,100
Same kit in single glass (U 1.1) Glazing becomes 20,770 about 23,600

One kilowatt-hour of electricity equals 3,412 Btu, so 14,100 Btu/hr is about 4.1 kW of continuous heat on that design night. A standard 1,500-watt plug-in heater delivers about 5,100 Btu/hr, which covers roughly 36 percent of the load. Expressed in propane, which carries about 91,500 Btu per gallon, the same night would burn around 0.15 gallons an hour before any heater losses.

As a cross-check, Colorado State University Extension suggests planning on about 200 Btu per hour per square foot of ground area to hold 50°F in a standard greenhouse when it is 10 below zero outside. For a 96-square-foot floor that gives 19,200 Btu/hr. Run at those same conditions, our method gives about 15,400 Btu/hr for twin-wall polycarbonate and 25,700 for single glass, so the rule of thumb lands between the two. This is the worst night, not every night, but the heater has to be sized for it.

Cut Heat Loss Before You Buy a Heater

Every Btu you stop losing is one you never pay for, and on a small greenhouse the cheap fixes can shrink the heater you need. The priorities are clear: seal leaks, insulate anything that does not need to transmit light, and add layers to the glazing.

Add a Second Layer

For single-layer houses, doubling the glazing is a major improvement. In the U-value table, going from single glass or single film (about 1.1) to a double layer (about 0.7) cuts conduction loss by more than a third. Double-layer polyethylene is estimated to save 20 to 30 percent of heat loss, and a thermal curtain pulled at night can reduce nighttime heat loss through the covered surfaces by about 50 percent.

Horticultural bubble wrap fixed inside the glazing is the hobby version of that second layer. We found no published U-value for it, so its exact benefit is unmeasured. The trade-off is light: a layer of plastic cuts out about 10 percent of light, which affects growth, though that is considered worthwhile to keep heating bills down.

Seal Gaps and Insulate the Base and North Wall

Locating and plugging holes in the greenhouse envelope generally reduces infiltration heat losses by 3 to 10 percent. On a kit, check the door, the vents and where panels meet the frame.

Perimeter heat loss is taken as 0.8 Btu/hr per foot per degree when uninsulated and 0.4 when insulated, so insulating the perimeter halves that part of the loss. For new construction, use 1- or 2-inch foam board installed to a depth of 24 inches or more around the perimeter, and consider insulating all opaque surfaces on north walls. In our example, swapping the north long wall (66 square feet) for 2-inch foam board and insulating the perimeter brings the design load from about 14,100 to about 11,400 Btu/hr, a cut of roughly 19 percent. The cost is the light that wall would have let in. University of Wisconsin Extension warns that foam is flammable and should be kept away from heat sources, and it recommends foam board faced with aluminum foil for better flame resistance.

Two operating habits also help. Running a 10°F day-night temperature differential on a day-night programmable controller can save 5 percent in heating energy, and having the heating system inspected and serviced once a year can reduce fuel costs by up to 20 percent, which usually pays for the service.

Thermal Mass: Useful, but Smaller Than It Sounds

Water barrels soak up daytime heat and release it at night, and water is one of the traditional storage materials in passive solar greenhouses. The physics sets a limit, though. One Btu raises one pound of water by 1°F, and a full 55-gallon barrel weighs more than 450 pounds. If that barrel cools by 10°F overnight, it gives back about 4,500 Btu, which is around 20 minutes of the 14,100 Btu/hr design load in our example.

In a University of Georgia passive solar study, researchers found their barrel-walled greenhouse could start warm-season crops at least a month earlier than a traditional high tunnel, yet it did not show large differences in nighttime temperatures compared with high tunnels. Thermal mass can smooth swings; it does not replace a heater in a cold climate. Plan for the weight, too: the Georgia team cabled its stacked barrels to posts for stability.

Choosing a Heater Type

The right heater depends on your load, fuel options and tolerance for risk. The usual fuels are electricity, bottled gas, natural gas, wood and fuel oil, and economics will dictate the choice.

Electric Fan and Tube Heaters

Electric heat is simple: no fuel to store and nothing to vent. The downside is cost and capacity. Electric heat can be very costly and is usually used only in very small greenhouses, and our example shows why: one 1,500-watt heater covers about a third of an 8×12 kit’s cold-region design load.

There is a useful distinction between the two. Greenhouse fan heaters typically provide more heat and move the air, which helps avoid cold corners and gives more even heat. Tube heaters are typically lower-powered and provide background heat to help keep frost at bay. The Royal Horticultural Society (RHS) advises buying a heater specifically sold for greenhouses to ensure safety. Ordinary household space heaters are a poor fit for an unattended overnight load: the CPSC’s January 2026 winter safety release says to turn off heaters when sleeping, to plug electric space heaters directly into a wall outlet and never into an extension cord or power strip, and to keep portable heaters at least three feet from combustible materials.

Oil-Filled Radiators

Oil-filled radiators are quiet and fanless, which makes them tempting. Read the manual first. One major manufacturer’s manual for a 1,500-watt model states “Do not use the appliance outdoors,” says the heater is not intended for bathrooms, laundry areas or similar locations, and warns against using an extension cord or outlet strip. A humid greenhouse is closer to those conditions than to a living room, so a household radiator may not be rated for it. Without a fan, they also lack the air movement that helps fan heaters avoid cold corners.

Propane and Natural Gas

Gas becomes worth considering when the load outgrows what plug-in electric heaters can supply, but it brings combustion hazards. Burning gas or paraffin produces water, ethylene and carbon monoxide, and the RHS says the greenhouse needs ventilating to avoid a build-up of these combustion products. This matters most with an unvented heater, which has no flue and releases its combustion products into the greenhouse. A UMass Extension fact sheet credited to University of Connecticut agricultural engineer John Bartok adds that ethylene levels as low as 0.01 ppm can malform leaves and flowers and stunt growth, and that an unvented heater needs a free air inlet of at least 1 square inch per 1,000 Btu/hr of input to replace the oxygen the burner uses. A 20,000 Btu/hr heater needs at least 20 square inches. That inlet is a minimum for combustion air, not a complete safety specification: the combustion gases and moisture from an unvented heater still go into the greenhouse air, and Bartok advises care with unvented heaters, an adequate makeup air supply and frequent maintenance.

A vented heater sends flue gases outside through a chimney, and Bartok notes that the combustion moisture leaves with them. University of Georgia Extension advises a fresh air supply and an unobstructed chimney so carbon monoxide will not build up. The US Consumer Product Safety Commission adds that unvented gas space heaters require oxygen depletion sensors and that gas and kerosene heaters should be inspected annually. Its home heating advice also calls for a carbon monoxide alarm outside each sleeping area. The CPSC does not address greenhouses, but a CO alarm is a reasonable extra precaution if you work in one with a combustion heater. If you add one, check that its stated operating temperature and humidity range covers conditions in your greenhouse, and treat it as a backup to venting, not a substitute for it.

Before installing a gas line or fixed gas heater, check who is allowed to do the work with your provincial fuel safety regulator or your local building department, and see Do You Need a Permit for a Greenhouse? for how local approvals work.

Kerosene and Paraffin

Kerosene, usually called paraffin in Britain when used for heating, is an option where there is no power. Writing about domestic greenhouses, the RHS says the ventilation gas and paraffin heaters need reduces their heating effect, so they are only really useful for plants that can withstand quite low temperatures. It also rates these fuels as the least environmentally friendly options. Georgia Extension recommends high-grade, low-sulfur kerosene to avoid sulfur dioxide damage, and Bartok notes that sulfur dioxide levels as low as half a part per million can injure some plants. The CPSC says kerosene heaters must have an automatic cut-off that puts out the flame if the unit tips over. An unvented kerosene heater, then, suits frost protection rather than a warm growing greenhouse.

Thermostats, Thermometers and Alarms

A good thermostat is what turns a heater into a heating system. Place thermostats at bench level in the center of the greenhouse, so they read the temperature the plants actually experience.

Because built-in heater thermostats can be off by a few degrees, it helps to place a thermometer in the middle of the greenhouse close to most of the plants. A maximum and minimum thermometer shows what happened overnight. A battery-operated high and low temperature alarm is also worth adding, since it covers heater failures and power cuts as well as overheating on sunny days. Thermostats should also be calibrated as part of annual heating maintenance.

Electrical Safety for an Outdoor Heater

A greenhouse mixes water, humidity and electricity. The CPSC describes a ground fault circuit interrupter (GFCI) as a device that constantly monitors current and cuts power faster than the blink of an eye to prevent a lethal shock. According to the CPSC, the US National Electrical Code has required GFCI protection on outdoor receptacles since 1973, and the agency recommends testing every GFCI at least once a month and after a power failure.

Avoid running a heater from a household extension cord. Ontario’s Electrical Safety Authority says not to use interior-rated cords outdoors, and the oil-filled radiator manual quoted above prohibits extension cords entirely. The RHS’s advice is simply to have the electrical connection to the greenhouse installed professionally.

The legal side differs by country and province. In Ontario, ESA says almost all electrical work requires a notification of work filed with ESA, and if you hire someone, it must by law be a Licensed Electrical Contracting Business. Other provinces and US states have their own rules, so check locally. Given loads like our example, which call for several kilowatts of heat through the night, have a licensed electrical contractor plan any new circuit to the greenhouse.

How the Plan Changes by Climate

Because heat loss scales with the temperature difference, the same twin-wall 8×12 kit needs very different heating in different places.

In a mild climate where winter nights bottom out around 20°F, holding 40°F frost-free means a 20-degree difference and about 5,100 Btu/hr, roughly what one 1,500-watt heater delivers. Holding 45°F pushes that to about 6,400 Btu/hr. One electric heater is borderline here, so sealing and a second layer are what give it headroom.

In a cold climate with design nights near -10°F, the load climbs to about 14,100 Btu/hr at 45°F. Sealing, perimeter and north-wall insulation and a second layer pay off here, and electric heat alone gets expensive. Realistic options are a frost-free target, heating only for a late-winter seed-starting window, or vented gas heat.

In a very cold, snowy climate with nights reaching -30°F, holding 45°F means a 75-degree difference and about 19,300 Btu/hr for the same kit before any adjustment. When the difference between the inside set point and the outside design temperature is larger than 70°F, or average wind speeds are higher than 15 mph, the overall heat loss should be multiplied by a factor larger than one, so treat 19,300 as a minimum. Triple-wall glazing, a fully insulated base and north wall, and a vented fuel heater sized with headroom are all worth considering, and a warm 60°F greenhouse may simply not be economical in midwinter. Snow brings its own structural concerns, covered in Greenhouse Snow Load Ratings.

Whatever your climate, run the numbers with your own dimensions before buying anything. The formula tells you whether one plug-in heater is enough or whether you are really shopping for insulation, a new circuit or a gas line.

Sources

Image Credit

  • Featured image: Alaska Bounty high tunnel in Naknek, by Blueelectricstorm, Wikimedia Commons, public domain